{"id":5172,"date":"2021-06-20T01:16:32","date_gmt":"2021-06-20T01:16:32","guid":{"rendered":"https:\/\/www.medicalmate.net\/?p=5172"},"modified":"2021-06-20T01:16:32","modified_gmt":"2021-06-20T01:16:32","slug":"medical-waste-incinerator-50-c-60kg-hr","status":"publish","type":"post","link":"https:\/\/incinerators.hiclover.com\/index.php\/2021\/06\/20\/medical-waste-incinerator-50-c-60kg-hr\/","title":{"rendered":"MEDICAL WASTE INCINERATOR (50 C 60kg\/hr)"},"content":{"rendered":"<figure class=\"post-featured-image\"><img loading=\"lazy\" width=\"1280\" height=\"1084\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26d7c592ad.jpg\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"\" sizes=\"(max-width: 1280px) 100vw, 1280px\" \/><\/figure>\n<div class=\"entry-content clearfix\">\n<div>\n<div><span style=\"color: rgb(0, 0, 0); background-color: rgba(0, 0, 0, 0);\">Medical&nbsp;Waste&nbsp;Incinerator,&nbsp;50&nbsp;to&nbsp;60&nbsp;Kg\/hr<br \/>\nSupport Health&nbsp;Sector&nbsp;Support&nbsp;Project<br \/>\nPoint&nbsp;of&nbsp;Installation&nbsp;(Hospitals) Moi&nbsp;Voi,&nbsp;Makindu,&nbsp;Maragua,&nbsp;Eldama&nbsp;Ravine&nbsp;and&nbsp;Isiolo&nbsp;District&nbsp;Hospitals<br \/>\n1.&nbsp;&nbsp;&nbsp;&nbsp;General&nbsp;Description<br \/>\nSupply,&nbsp;delivery,&nbsp;installation&nbsp;and&nbsp;commissioning&nbsp;of&nbsp;a&nbsp;medical&nbsp;waste&nbsp;incinerator&nbsp;suitable&nbsp;for&nbsp;disposal&nbsp;of&nbsp;Medical,&nbsp;General&nbsp;and&nbsp;Pathological&nbsp;waste&nbsp;in&nbsp;a&nbsp;safe&nbsp;and&nbsp;clean&nbsp;environment.&nbsp;&nbsp;The&nbsp;unit&nbsp;shall&nbsp;consist&nbsp;of&nbsp;two&nbsp;chambers&nbsp;and&nbsp;operate&nbsp;on&nbsp;the&nbsp;principal&nbsp;of&nbsp;controlled&nbsp;air&nbsp;and&nbsp;temperature.&nbsp;The&nbsp;unit&nbsp;shall&nbsp;consist&nbsp;a&nbsp;particulate&nbsp;remover&nbsp;(scrubbers)&nbsp;as&nbsp;stipulated&nbsp;in&nbsp;waste&nbsp;management&nbsp;regulations,&nbsp;2006&nbsp;(Legal&nbsp;notice&nbsp;NO.&nbsp;121&nbsp;of&nbsp;29th&nbsp;September,&nbsp;2006).&nbsp;&nbsp;The&nbsp;Unit&nbsp;shall&nbsp;be&nbsp;fully&nbsp;automatic&nbsp;and&nbsp;controlled&nbsp;by&nbsp;an&nbsp;automatic&nbsp;electronic&nbsp;controlled&nbsp;system&nbsp;except&nbsp;loading&nbsp;system&nbsp;which&nbsp;shall&nbsp;be&nbsp;manual.&nbsp;&nbsp;The&nbsp;unit&nbsp;shall&nbsp;be&nbsp;capable&nbsp;of&nbsp;incinerating&nbsp;between&nbsp;50&nbsp;to&nbsp;60&nbsp;kg&nbsp;of&nbsp;solid&nbsp;medical&nbsp;waste&nbsp;per&nbsp;hour.&nbsp;&nbsp;It&nbsp;shall&nbsp;be&nbsp;constructed&nbsp;from&nbsp;mild&nbsp;or&nbsp;aluminized&nbsp;steel&nbsp;lined&nbsp;with&nbsp;refractory&nbsp;material.<br \/>\nMain&nbsp;unit<br \/>\nApplication For&nbsp;incineration,&nbsp;general&nbsp;and&nbsp;pathological<br \/>\nCapacity&nbsp;&nbsp; 50&nbsp;C&nbsp;60&nbsp;kg\/h&nbsp;burn&nbsp;rate<br \/>\nType Two&nbsp;&nbsp;combustion&nbsp;chambers&nbsp;type;&nbsp;primary&nbsp;&nbsp;and&nbsp;Secondary,&nbsp;controlled\/forced&nbsp;combustion&nbsp;air&nbsp;type&nbsp;with&nbsp;a&nbsp;flue&nbsp;gas&nbsp;emission&nbsp;scrubbing&nbsp;unit<br \/>\nOperating&nbsp;time&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Minimum&nbsp;8&nbsp;hours&nbsp;daily<br \/>\nOperating&nbsp;temperature&nbsp;&nbsp;&nbsp;&nbsp; From&nbsp;850&nbsp;0C&nbsp;to&nbsp;1200&nbsp;0C,&nbsp;Automatic&nbsp;controlled<br \/>\nResidual&nbsp;Ash&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 5&nbsp;to&nbsp;10%<br \/>\n&nbsp;&nbsp;&nbsp;&nbsp;3.2&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Primary&nbsp;Chamber<br \/>\nConstruction Constructed&nbsp;from&nbsp;heavy&nbsp;duty&nbsp;mild&nbsp;or&nbsp;aluminized&nbsp;&nbsp;steel&nbsp;Or<br \/>\nequal&nbsp;and&nbsp;approved&nbsp;equivalent<br \/>\nInsulation&nbsp;material&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Refractory&nbsp;material&nbsp;lining&nbsp;similar&nbsp;or&nbsp;equal&nbsp;to&nbsp;calcium&nbsp;<br \/>\nSilicate&nbsp;and&nbsp;hot&nbsp;face&nbsp;combination&nbsp;of&nbsp;heavy&nbsp;duty&nbsp;brickwork<br \/>\nInternal&nbsp;Construction&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Fixed&nbsp;hearth&nbsp;type&nbsp;complete&nbsp;with&nbsp;gratings,&nbsp;concave&nbsp;bottom<br \/>\nand&nbsp;charging&nbsp;door,&nbsp;lined&nbsp;with&nbsp;refractory&nbsp;material<br \/>\nCharging&nbsp;Door&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Suitable&nbsp;for&nbsp;manual&nbsp;loading&nbsp;of&nbsp;wastes&nbsp;and&nbsp;with&nbsp;smooth&nbsp;<br \/>\nDear&nbsp;seal&nbsp;equivalent&nbsp;of&nbsp;Ceramic&nbsp;seals&nbsp;with&nbsp;hinges.<br \/>\nDoor&nbsp;Lock&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Automatic,&nbsp;Electric&nbsp;type<br \/>\nAsh&nbsp;removal&nbsp;door&nbsp;&nbsp;&nbsp; Provided,&nbsp;for&nbsp;removing&nbsp;resultant&nbsp;bottom&nbsp;ash&nbsp;leftovers&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;from&nbsp;the&nbsp;Primary&nbsp;chamber<br \/>\nGratings&nbsp;&nbsp; Provided<br \/>\nLoading Manual&nbsp;loading&nbsp;of&nbsp;waste<br \/>\nPrimary&nbsp;Burner&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Fully&nbsp;automatic,&nbsp;with&nbsp;fuel,&nbsp;temperature&nbsp;and&nbsp;speed&nbsp;controls&nbsp;with&nbsp;ignition&nbsp;system,&nbsp;flame&nbsp;detector,&nbsp;Air&nbsp;fan&nbsp;complete&nbsp;with&nbsp;safety&nbsp;features,&nbsp;flame&nbsp;failure,&nbsp;&nbsp;Diesel&nbsp;fired&nbsp;fuel&nbsp;injector&nbsp;type&nbsp;and&nbsp;Flange&nbsp;mounted&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br \/>\nBlower Provided.&nbsp;For&nbsp;supplying&nbsp;excess&nbsp;combustion&nbsp;air&nbsp;through&nbsp;the&nbsp;distribution&nbsp;system&nbsp;with&nbsp;speed&nbsp;control&nbsp;system<br \/>\nTemperature Minimum&nbsp;exit&nbsp;850&nbsp;0C<br \/>\nObservation&nbsp;port To&nbsp;be&nbsp;provided&nbsp;with&nbsp;protective&nbsp;glass&nbsp;type<br \/>\nConstruction&nbsp;&nbsp; Constructed&nbsp;from&nbsp;heavy&nbsp;duty&nbsp;mild&nbsp;or&nbsp;aluminized&nbsp;steel&nbsp;or&nbsp;equal&nbsp;and&nbsp;approved&nbsp;equivalent<br \/>\nInsulation Refractory&nbsp;material&nbsp;lining<br \/>\nCombustion&nbsp;Temperatures&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Above&nbsp;850&nbsp;0C,&nbsp;controlled&nbsp;electronically<br \/>\nGas&nbsp;residue&nbsp;or&nbsp;retention&nbsp;Time&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &gt;&nbsp;2&nbsp;second&nbsp;at&nbsp;minimum&nbsp;850&nbsp;0C<br \/>\nSecondary&nbsp;Burner&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Provided,&nbsp;Diesel&nbsp;fired,&nbsp;fully&nbsp;automatic,&nbsp;with&nbsp;fuel,&nbsp;temperature&nbsp;and&nbsp;speed&nbsp;controls,&nbsp;With&nbsp;ignition&nbsp;system,&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Flame&nbsp;detector,&nbsp;Air&nbsp;fan,&nbsp;Complete&nbsp;with&nbsp;safety&nbsp;features,&nbsp;flame&nbsp;failure&nbsp;Diesel&nbsp;fired&nbsp;fuel&nbsp;injector&nbsp;type.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Flange&nbsp;mounted<br \/>\nEjector Provided,&nbsp;Venturi&nbsp;type,&nbsp;for&nbsp;cooling&nbsp;the&nbsp;flue&nbsp;gases<br \/>\nCombustion&nbsp;Air&nbsp;Fan Provided&nbsp;for&nbsp;supplying&nbsp;combustion&nbsp;and&nbsp;creating&nbsp;a&nbsp;negative&nbsp;drift&nbsp;and&nbsp;turbulences<br \/>\nTemperature Maximum&nbsp;&nbsp;1600&nbsp;0C<\/span><\/div>\n<\/div>\n<div id='gallery-2' class='gallery galleryid-420 gallery-columns-3 gallery-size-thumbnail'>\n<figure class='gallery-item'>\n<div class='gallery-icon landscape'><a href='https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/eclover'><img loading=\"lazy\" width=\"150\" height=\"150\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26d7cd6250.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a><\/div>\n<\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Medical&nbsp;Waste&nbsp;Incinerator,&nbsp;50&nbsp;to&nbsp;60&nbsp;Kg\/hr Support Health&nbsp;Sector&nbsp;Support&nbsp;Project Point&nbsp;of&nbsp;Installation&nbsp;(Hospitals) Moi&nbsp;Voi,&nbsp;Makindu,&nbsp;Maragua,&nbsp;Eldama&nbsp;Ravine&nbsp;and&nbsp;Isiolo&nbsp;District&nbsp;Hospitals 1.&nbsp;&nbsp;&nbsp;&nbsp;General&nbsp;Description Supply,&nbsp;delivery,&nbsp;installation&nbsp;and&nbsp;commissioning&nbsp;of&nbsp;a&nbsp;medical&nbsp;waste&nbsp;incinerator&nbsp;suitable&nbsp;for&nbsp;disposal&nbsp;of&nbsp;Medical,&nbsp;General&nbsp;and&nbsp;Pathological&nbsp;waste&nbsp;in&nbsp;a&nbsp;safe&nbsp;and&nbsp;clean&nbsp;environment.&nbsp;&nbsp;The&nbsp;unit&nbsp;shall&nbsp;consist&nbsp;of&nbsp;two&nbsp;chambers&nbsp;and&nbsp;operate&nbsp;on&nbsp;the&nbsp;principal&nbsp;of&nbsp;controlled&nbsp;air&nbsp;and&nbsp;temperature.&nbsp;The&nbsp;unit&nbsp;shall&nbsp;consist&nbsp;a&nbsp;particulate&nbsp;remover&nbsp;(scrubbers)&nbsp;as&nbsp;stipulated&nbsp;in&nbsp;waste&nbsp;management&nbsp;regulations,&nbsp;2006&nbsp;(Legal&nbsp;notice&nbsp;NO.&nbsp;121&nbsp;of&nbsp;29th&nbsp;September,&nbsp;2006).&nbsp;&nbsp;The&nbsp;Unit&nbsp;shall&nbsp;be&nbsp;fully&nbsp;automatic&nbsp;and&nbsp;controlled&nbsp;by&nbsp;an&nbsp;automatic&nbsp;electronic&nbsp;controlled&nbsp;system&nbsp;except&nbsp;loading&nbsp;system&nbsp;which&nbsp;shall&nbsp;be&nbsp;manual.&nbsp;&nbsp;The&nbsp;unit&nbsp;shall&nbsp;be&nbsp;capable&nbsp;of&nbsp;incinerating&nbsp;between&nbsp;50&nbsp;to&nbsp;60&nbsp;kg&nbsp;of&nbsp;solid&nbsp;medical&nbsp;waste&nbsp;per&nbsp;hour.&nbsp;&nbsp;It&nbsp;shall&nbsp;be&nbsp;constructed&nbsp;from&nbsp;mild&nbsp;or&nbsp;aluminized&nbsp;steel&nbsp;lined&nbsp;with&nbsp;refractory&nbsp;material. Main&nbsp;unit Application For&nbsp;incineration,&nbsp;general&nbsp;and&nbsp;pathological Capacity&nbsp;&nbsp; 50&nbsp;C&nbsp;60&nbsp;kg\/h&nbsp;burn&nbsp;rate Type Two&nbsp;&nbsp;combustion&nbsp;chambers&nbsp;type;&nbsp;primary&nbsp;&nbsp;and&nbsp;Secondary,&nbsp;controlled\/forced&nbsp;combustion&nbsp;air&nbsp;type&nbsp;with&nbsp;a&nbsp;flue&nbsp;gas&nbsp;emission&nbsp;scrubbing&nbsp;unit Operating&nbsp;time&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Minimum&nbsp;8&nbsp;hours&nbsp;daily Operating&nbsp;temperature&nbsp;&nbsp;&nbsp;&nbsp; From&nbsp;850&nbsp;0C&nbsp;to&nbsp;1200&nbsp;0C,&nbsp;Automatic&nbsp;controlled Residual&nbsp;Ash&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 5&nbsp;to&nbsp;10%<\/p>\n","protected":false},"author":1,"featured_media":5175,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[129],"tags":[139,753,610,143,321,228,221,754,755,488,160,152,489,136],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/5172"}],"collection":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/comments?post=5172"}],"version-history":[{"count":0,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/5172\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media\/5175"}],"wp:attachment":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media?parent=5172"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/categories?post=5172"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/tags?post=5172"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}