{"id":5188,"date":"2021-06-20T16:17:00","date_gmt":"2021-06-20T16:17:00","guid":{"rendered":"https:\/\/www.medicalmate.net\/?p=5188"},"modified":"2021-06-20T16:17:00","modified_gmt":"2021-06-20T16:17:00","slug":"hot-medical-waste-disposing-machine-operation-condition-8-16-hr-day-2","status":"publish","type":"post","link":"https:\/\/incinerators.hiclover.com\/index.php\/2021\/06\/20\/hot-medical-waste-disposing-machine-operation-condition-8-16-hr-day-2\/","title":{"rendered":"hot medical waste disposing machine, Operation Condition: 8-16 hr\/ day"},"content":{"rendered":"<figure class=\"post-featured-image\"><img loading=\"lazy\" width=\"450\" height=\"300\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26d8889dde.jpg\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"\" sizes=\"(max-width: 450px) 100vw, 450px\" \/><\/figure>\n<div class=\"entry-content clearfix\">\n<div>\n<div><span style=\"color: rgb(0, 0, 0); background-color: rgba(0, 0, 0, 0);\">hot&nbsp;medical&nbsp;waste&nbsp;disposing&nbsp;machine,&nbsp;Operation&nbsp;Condition:&nbsp;8-16&nbsp;hr\/&nbsp;day&nbsp;<br \/>\nControl:&nbsp;Built-in&nbsp;data&nbsp;recording<br \/>\nOperating&nbsp;temperature:&nbsp;Incinerator&nbsp;<br \/>\n\/Primary&nbsp;Combustion&nbsp;Chamber<br \/>\nPrimary&nbsp;Chamber:&nbsp;900&nbsp;\u2013&nbsp;1200&nbsp;0C<\/p>\n<p><\/span><\/p>\n<p><span style=\"color: rgb(0, 0, 0); background-color: rgba(0, 0, 0, 0);\">Type:&nbsp;continuous&nbsp;loading,&nbsp;Top&nbsp;Loading<br \/>\nCapacity\/Burn&nbsp;rate&nbsp;per&nbsp;hour:&nbsp;250&nbsp;-300&nbsp;kg\/hr&nbsp;<br \/>\nMaterial:<br \/>\nExternal-&nbsp;3&nbsp;layers&nbsp;<br \/>\nInternal&nbsp;lining:&nbsp;&nbsp;a&nbsp;fire&nbsp;proof&nbsp;material&nbsp;of&nbsp;pre-fired&nbsp;refractory&nbsp;bricks&nbsp;with&nbsp;Aluminium&nbsp;lining,&nbsp;resistant&nbsp;to&nbsp;corrosive&nbsp;waste&nbsp;or&nbsp;gas&nbsp;and&nbsp;to&nbsp;thermal&nbsp;shock<br \/>\nSecondary&nbsp;<br \/>\nCombustion&nbsp;<br \/>\nChamber:<\/span><img src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26d892583e.jpg\" border=\"0\" \/><span style=\"color: rgb(0, 0, 0); background-color: rgba(0, 0, 0, 0);\"><br \/>\nType:&nbsp;horizontal\/vertical<br \/>\nTemperature:&nbsp;&nbsp;1200-&nbsp;1300&nbsp;oC<br \/>\nResidence&nbsp;time&nbsp;of&nbsp;gases&nbsp;:&nbsp;&gt;2&nbsp;seconds<br \/>\nAsh&nbsp;Residue:&nbsp;&lt;5%&nbsp;of&nbsp;original&nbsp;waste&nbsp;size<br \/>\nAsh&nbsp;Handling&nbsp;System:&nbsp;Both&nbsp;Automatic&nbsp;and&nbsp;manual&nbsp;removal&nbsp;of&nbsp;Ash.&nbsp;Must&nbsp;ensure&nbsp;removal\/treatment&nbsp;of&nbsp;hazardous&nbsp;remnants&nbsp;of&nbsp;ash<br \/>\nFlue&nbsp;gas&nbsp;treatment&nbsp;&nbsp;&nbsp;system&nbsp;:&nbsp;Capable&nbsp;of&nbsp;treating&nbsp;the&nbsp;flow&nbsp;of&nbsp;flue&nbsp;&nbsp;gas&nbsp;as&nbsp;the&nbsp;incinerator&nbsp;is&nbsp;operating&nbsp;at&nbsp;its&nbsp;maximum&nbsp;capacity<br \/>\nAuxiliary&nbsp;device:&nbsp;Water&nbsp;level&nbsp;gauge,&nbsp;pressure&nbsp;sensor,&nbsp;PH&nbsp;sensor..etc&nbsp;<br \/>\nAuxiliary&nbsp;device:&nbsp;Fuel&nbsp;cut-off&nbsp;device<br \/>\nWaste&nbsp;&nbsp;feeding&nbsp;mechanism:&nbsp;Automatic&nbsp;pneumatic\/hydraulic&nbsp;waste&nbsp;loading&nbsp;system&nbsp;or&nbsp;conveyor&nbsp;belt&nbsp;,&nbsp;capacity&nbsp;650-800&nbsp;L&nbsp;at&nbsp;a&nbsp;time&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br \/>\nChimney&nbsp;(Stack):<br \/>\nType:&nbsp;Vertical&nbsp;type<br \/>\nheight:&gt;7&nbsp;meter\u2019<br \/>\nMaterial:&nbsp;Fireproof&nbsp;cast,&nbsp;stainless&nbsp;steel<br \/>\nOUTPUT:&nbsp;<br \/>\nGAS-&nbsp;SMOKELESS,ODORLESS&nbsp;<br \/>\nASH&nbsp;-Max&nbsp;&lt;5%&nbsp;of&nbsp;original&nbsp;waste&nbsp;size<br \/>\nReduction&nbsp;of&nbsp;Pollutant&nbsp;gas&nbsp;SO2,&nbsp;HCL,&nbsp;HF&nbsp;and&nbsp;line&nbsp;particulate<br \/>\nEmission&nbsp;standard:<br \/>\nWHO\/&nbsp;European<br \/>\nTest&nbsp;report&nbsp;for&nbsp;emission&nbsp;testing&nbsp;provided?<br \/>\nHeat&nbsp;exchange&nbsp;mode:&nbsp;Automatic<\/span><\/p>\n<p><span style=\"color: rgb(0, 0, 0); background-color: rgba(0, 0, 0, 0);\">Accessories:&nbsp;&nbsp;<br \/>\nAll&nbsp;standard&nbsp;accessories&nbsp;for&nbsp;incinerator,&nbsp;including&nbsp;but&nbsp;not&nbsp;limited&nbsp;to&nbsp;loading&nbsp;system,&nbsp;heat&nbsp;exchangers,&nbsp;pollution&nbsp;control&nbsp;system,&nbsp;ash&nbsp;removal&nbsp;system,&nbsp;including&nbsp;ladder&nbsp;and&nbsp;oil&nbsp;tanker&nbsp;(2500litre&nbsp;capacity).<br \/>\nOperating&nbsp;Environment:&nbsp;<br \/>\nThe&nbsp;incinerator&nbsp;is&nbsp;capable&nbsp;to&nbsp;operate&nbsp;at&nbsp;the&nbsp;altitude&nbsp;of&nbsp;2400mt&nbsp;above&nbsp;sea&nbsp;level.&nbsp;(according&nbsp;to&nbsp;the&nbsp;site&nbsp;conditions)<br \/>\nPower&nbsp;Requirement:<br \/>\n220&nbsp;Vac&nbsp;single&nbsp;phase&nbsp;or&nbsp;380&nbsp;Vac&nbsp;three&nbsp;phase&nbsp;4&nbsp;wire&nbsp;system&nbsp;&nbsp;50HZ&nbsp;&nbsp;&nbsp;<br \/>\nInstallation&nbsp;Testing&nbsp;and&nbsp;Commissioning&nbsp;:&nbsp;&nbsp;&nbsp;to&nbsp;be&nbsp;conducted&nbsp;by&nbsp;certified&nbsp;or&nbsp;qualified&nbsp;personnel.&nbsp;&nbsp;<br \/>\nSupplier&nbsp;shall&nbsp;provide&nbsp;the&nbsp;following&nbsp;documentation&nbsp;&nbsp;&nbsp;&nbsp;<br \/>\n\uf0a7User&nbsp;(Operating)&nbsp;manual&nbsp;in&nbsp;English.&nbsp;<br \/>\n\uf0a7Service&nbsp;(Technical&nbsp;\/&nbsp;Maintenance)&nbsp;manual&nbsp;in&nbsp;English.&nbsp;<br \/>\n\uf0a7Certificate&nbsp;of&nbsp;calibration&nbsp;and&nbsp;inspection&nbsp;from&nbsp;factory.&nbsp;<br \/>\nFast&nbsp;moving&nbsp;spare&nbsp;parts:&nbsp;Supplier&nbsp;is&nbsp;able&nbsp;to&nbsp;provide&nbsp;fast&nbsp;moving&nbsp;spare&nbsp;parts&nbsp;with&nbsp;quantities&nbsp;as&nbsp;described&nbsp;in&nbsp;the&nbsp;price&nbsp;schedule&nbsp;or&nbsp;their&nbsp;equivalent.&nbsp;<br \/>\nTraining:&nbsp;Supplier&nbsp;is&nbsp;able&nbsp;to&nbsp;provide&nbsp;training&nbsp;on&nbsp;operation,&nbsp;management&nbsp;and&nbsp;maintenance&nbsp;of&nbsp;incinerators.&nbsp;&nbsp;&nbsp;<br \/>\nWarranty&nbsp;<br \/>\nComprehensive&nbsp;warranty&nbsp;for&nbsp;minimum&nbsp;2&nbsp;year.&nbsp;<br \/>\nMaintenance&nbsp;Service&nbsp;during&nbsp;Warranty&nbsp;Period&nbsp;<br \/>\nDuring&nbsp;warranty&nbsp;period&nbsp;supplier&nbsp;must&nbsp;ensure,&nbsp;corrective\/breakdown&nbsp;maintenance&nbsp;whenever&nbsp;required.&nbsp;<br \/>\nSupplier&nbsp;has&nbsp;a&nbsp;local&nbsp;agent&nbsp;or&nbsp;branch&nbsp;office&nbsp;in&nbsp;Ethiopia&nbsp;(please&nbsp;indicate&nbsp;the&nbsp;name&nbsp;and&nbsp;contact&nbsp;details&nbsp;of&nbsp;the&nbsp;agent)&nbsp;<br \/>\nSupplier&nbsp;provides&nbsp;labor,&nbsp;lifting&nbsp;equipment&nbsp;and&nbsp;tools&nbsp;needed&nbsp;for&nbsp;the&nbsp;installation,&nbsp;testing&nbsp;and&nbsp;commissioning&nbsp;of&nbsp;the&nbsp;incinerator.&nbsp;The&nbsp;supplier&nbsp;will&nbsp;be&nbsp;responsible&nbsp;for&nbsp;the&nbsp;safety&nbsp;of&nbsp;its&nbsp;staff,&nbsp;workers&nbsp;and&nbsp;laborers&nbsp;during&nbsp;the&nbsp;installation,&nbsp;testing&nbsp;&amp;&nbsp;commisssioning&nbsp;<br \/>\nAble&nbsp;to&nbsp;provides&nbsp;all&nbsp;necessary&nbsp;information&nbsp;that&nbsp;would&nbsp;be&nbsp;used&nbsp;as&nbsp;an&nbsp;input&nbsp;for&nbsp;preparation&nbsp;of&nbsp;floor&nbsp;(platform)&nbsp;and&nbsp;room&nbsp;for&nbsp;the&nbsp;incinerator&nbsp;to&nbsp;be&nbsp;supplied&nbsp;such&nbsp;as&nbsp;the&nbsp;following;&nbsp;<br \/>\n\uf0fcLay&nbsp;outs&nbsp;(drawings)&nbsp;and&nbsp;&nbsp;pictures&nbsp;of&nbsp;the&nbsp;incinerators&nbsp;to&nbsp;be&nbsp;installed&nbsp;<br \/>\n\uf0fc&nbsp;Length,&nbsp;width&nbsp;and&nbsp;height&nbsp;of&nbsp;incinerator,<br \/>\n\uf0fc&nbsp;Area&nbsp;(length&nbsp;x&nbsp;width)&nbsp;for&nbsp;the&nbsp;floor&nbsp;(platform)&nbsp;and&nbsp;Length,&nbsp;width&nbsp;and&nbsp;height&nbsp;for&nbsp;roofing,&nbsp;for&nbsp;each&nbsp;type&nbsp;of&nbsp;incinerators&nbsp;to&nbsp;be&nbsp;installed&nbsp;<br \/>\n\uf0fcNeeds&nbsp;during&nbsp;the&nbsp;transport,&nbsp;installation,&nbsp;assembly,&nbsp;commissioning&nbsp;and&nbsp;operation&nbsp;of&nbsp;the&nbsp;equipment&nbsp;in&nbsp;terms&nbsp;of&nbsp;access&nbsp;points,&nbsp;available&nbsp;space&nbsp;to&nbsp;operate&nbsp;(inside&nbsp;and&nbsp;outside&nbsp;of&nbsp;the&nbsp;room),&nbsp;ways&nbsp;to&nbsp;get&nbsp;to&nbsp;the&nbsp;site&nbsp;where&nbsp;the&nbsp;equipment&nbsp;will&nbsp;be&nbsp;placed&nbsp;or&nbsp;any&nbsp;others.&nbsp;;&nbsp;<br \/>\n\uf0fcTechnical&nbsp;Specifications&nbsp;(fuel&nbsp;consumption&nbsp;rate,&nbsp;weight,&nbsp;anchoring&nbsp;system,&nbsp;support&nbsp;points,&nbsp;etc.);<br \/>\n\uf0fc&nbsp;Chimney&nbsp;specifications&nbsp;to&nbsp;be&nbsp;used&nbsp;for&nbsp;the&nbsp;roof&nbsp;design&nbsp;(&nbsp;size,&nbsp;support&nbsp;needs,&nbsp;insulation);&nbsp;<br \/>\n\uf0fcConsiderations&nbsp;related&nbsp;to&nbsp;operation&nbsp;and&nbsp;Maintenance,&nbsp;for&nbsp;e.g.,&nbsp;minimum&nbsp;available&nbsp;area&nbsp;to&nbsp;perform&nbsp;routine&nbsp;maintenance&nbsp;tasks&nbsp;and&nbsp;replacement&nbsp;of&nbsp;key&nbsp;parts&nbsp;that&nbsp;need&nbsp;to&nbsp;be&nbsp;changed&nbsp;more&nbsp;frequently;&nbsp;<br \/>\n\uf0fcAny&nbsp;consideration\/need&nbsp;of&nbsp;the&nbsp;incinerator&nbsp;while&nbsp;being&nbsp;operated&nbsp;that&nbsp;might&nbsp;impact&nbsp;the&nbsp;design&nbsp;of&nbsp;the&nbsp;room\/shelter&nbsp;where&nbsp;it&nbsp;will&nbsp;be&nbsp;placed.<br \/>\n\uf0fcOther&nbsp;important&nbsp;information&nbsp;to&nbsp;be&nbsp;considered&nbsp;that&nbsp;can&nbsp;influence&nbsp;or&nbsp;impact&nbsp;the&nbsp;designing&nbsp;and&nbsp;building&nbsp;processes&nbsp;of&nbsp;the&nbsp;infrastructure&nbsp;for&nbsp;the&nbsp;incinerators,&nbsp;for&nbsp;example&nbsp;area&nbsp;dimension&nbsp;for&nbsp;other&nbsp;accessary&nbsp;parts&nbsp;like&nbsp;fuel&nbsp;tanker&nbsp;storage,&nbsp;if&nbsp;applicable,&nbsp;etc\u2026.&nbsp;<br \/>\nDelivery&nbsp;time&nbsp;(DAP,&nbsp;Addis&nbsp;Ababa)&nbsp;in&nbsp;weeks<br \/>\nName&nbsp;of&nbsp;manufacturer&nbsp;including&nbsp;website&nbsp;of&nbsp;the&nbsp;manufacturer&nbsp;&amp;\/&nbsp;supplier&nbsp;&amp;&nbsp;country&nbsp;of&nbsp;origin<\/span><\/p>\n<\/div>\n<\/div>\n<div id='gallery-2' class='gallery galleryid-417 gallery-columns-3 gallery-size-thumbnail'>\n<figure class='gallery-item'>\n<div class='gallery-icon landscape'><a href='https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/temperature-display-and-program-set-up-ts-model-hiclover'><img loading=\"lazy\" width=\"150\" height=\"150\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26d898df34.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a><\/div>\n<\/figure>\n<figure class='gallery-item'>\n<div class='gallery-icon landscape'><a href='https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/insertpic_61d2'><img loading=\"lazy\" width=\"150\" height=\"150\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26d89ef40a.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a><\/div>\n<\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>hot&nbsp;medical&nbsp;waste&nbsp;disposing&nbsp;machine,&nbsp;Operation&nbsp;Condition:&nbsp;8-16&nbsp;hr\/&nbsp;day&nbsp; Control:&nbsp;Built-in&nbsp;data&nbsp;recording Operating&nbsp;temperature:&nbsp;Incinerator&nbsp; \/Primary&nbsp;Combustion&nbsp;Chamber Primary&nbsp;Chamber:&nbsp;900&nbsp;\u2013&nbsp;1200&nbsp;0C Type:&nbsp;continuous&nbsp;loading,&nbsp;Top&nbsp;Loading Capacity\/Burn&nbsp;rate&nbsp;per&nbsp;hour:&nbsp;250&nbsp;-300&nbsp;kg\/hr&nbsp; Material: External-&nbsp;3&nbsp;layers&nbsp; Internal&nbsp;lining:&nbsp;&nbsp;a&nbsp;fire&nbsp;proof&nbsp;material&nbsp;of&nbsp;pre-fired&nbsp;refractory&nbsp;bricks&nbsp;with&nbsp;Aluminium&nbsp;lining,&nbsp;resistant&nbsp;to&nbsp;corrosive&nbsp;waste&nbsp;or&nbsp;gas&nbsp;and&nbsp;to&nbsp;thermal&nbsp;shock Secondary&nbsp; Combustion&nbsp; Chamber: Type:&nbsp;horizontal\/vertical Temperature:&nbsp;&nbsp;1200-&nbsp;1300&nbsp;oC Residence&nbsp;time&nbsp;of&nbsp;gases&nbsp;:&nbsp;&gt;2&nbsp;seconds Ash&nbsp;Residue:&nbsp;&lt;5%&nbsp;of&nbsp;original&nbsp;waste&nbsp;size Ash&nbsp;Handling&nbsp;System:&nbsp;Both&nbsp;Automatic&nbsp;and&nbsp;manual&nbsp;removal&nbsp;of&nbsp;Ash.&nbsp;Must&nbsp;ensure&nbsp;removal\/treatment&nbsp;of&nbsp;hazardous&nbsp;remnants&nbsp;of&nbsp;ash Flue&nbsp;gas&nbsp;treatment&nbsp;&nbsp;&nbsp;system&nbsp;:&nbsp;Capable&nbsp;of&nbsp;treating&nbsp;the&nbsp;flow&nbsp;of&nbsp;flue&nbsp;&nbsp;gas&nbsp;as&nbsp;the&nbsp;incinerator&nbsp;is&nbsp;operating&nbsp;at&nbsp;its&nbsp;maximum&nbsp;capacity Auxiliary&nbsp;device:&nbsp;Water&nbsp;level&nbsp;gauge,&nbsp;pressure&nbsp;sensor,&nbsp;PH&nbsp;sensor..etc&nbsp;<\/p>\n","protected":false},"author":1,"featured_media":5194,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[129],"tags":[279,642,155,135,756,644,757,758,759,760,761,488,626,152,136],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/5188"}],"collection":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/comments?post=5188"}],"version-history":[{"count":0,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/5188\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media\/5194"}],"wp:attachment":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media?parent=5188"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/categories?post=5188"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/tags?post=5188"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}