{"id":5217,"date":"2021-06-21T17:18:07","date_gmt":"2021-06-21T17:18:07","guid":{"rendered":"https:\/\/www.medicalmate.net\/?p=5217"},"modified":"2021-06-21T17:18:07","modified_gmt":"2021-06-21T17:18:07","slug":"incinerator-with-capacity-of-destruction-in-weight-60-kg-h","status":"publish","type":"post","link":"https:\/\/incinerators.hiclover.com\/index.php\/2021\/06\/21\/incinerator-with-capacity-of-destruction-in-weight-60-kg-h\/","title":{"rendered":"Incinerator with Capacity of destruction in weight: 60 Kg\/h."},"content":{"rendered":"<figure class=\"post-featured-image\"><img loading=\"lazy\" width=\"449\" height=\"300\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26d9e4cd74.jpg\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"\" sizes=\"(max-width: 449px) 100vw, 449px\" \/><\/figure>\n<div class=\"entry-content clearfix\">\n<div>\n<div>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"font-family: 'Times New Roman'; font-size: 12pt;\">Capacity of destruction in weight: 60 Kg\/h.<\/span><\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt;\"><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">It should be able to operate not less than 10 hours\/day<\/span><\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"font-family: 'Times New Roman'; font-size: 12pt;\">This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc\u2026<\/span><\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">Design Specification<\/span><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; color:rgb(255,0,0);font-size:12.0000pt;\">&nbsp;:<\/span> <span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">Types A, B, C, D, and E of medical waste<\/span><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; color:rgb(255,0,0);font-size:12.0000pt;\">&nbsp;<\/span><\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"font-family: 'Times New Roman'; font-size: 12pt;\">\u201cPYROLYTIC\u201d combustion, by controlling the gasification of waste.<\/span><\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"font-family: 'Times New Roman'; font-size: 12pt;\">The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings.<\/span><\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt;\"><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">It should be able to reduce the volume of wastes by 98%.<\/span><\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt;\"><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.<\/span><\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">The incineration should be completely free from<\/span> <span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">visible smoke<\/span><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">&nbsp;as well as<\/span> <span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">offensive odours<\/span><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">.<\/span><\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt;\"><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">The lower calorific power (L.C.P) of this waste will be<\/span> <b><span style=\"font-family: 'Times New Roman'; font-size: 12pt;\">3,500 kcal\/kg<\/span><\/b><\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt; margin-left: 45pt;\"><span style=\"font-family: 'Times New Roman'; font-size: 12pt;\">The Temperatures of combustion:<\/span><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">&nbsp;Minimum will be 850<\/span><sup><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;vertical-align:super;\">o<\/span><\/sup><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">C and max 1400<\/span><sup><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;vertical-align:super;\">o<\/span><\/sup><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">C<\/span><\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt; margin-left: 45pt;\"><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">Post combustion:<\/span> <span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; color:rgb(255,0,0);font-size:12.0000pt;\">&gt;<\/span><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">1100<\/span><sup><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;vertical-align:super;\">o<\/span><\/sup><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">C.<\/span><\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"font-family: 'Times New Roman'; font-size: 12pt;\">The Internal diameter of the Chimney: \u00d8 400 and its height: 8 m<\/span><\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"font-family: 'Times New Roman'; font-size: 12pt;\">The Volume of the combustion chamber: 1.200 L<\/span><\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"font-family: 'Times New Roman'; font-size: 12pt;\">The Dimension of the door for loading in cm: 70\u00d770.<\/span><\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">Burner operation should be Automatic On\/Off<\/span><\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"mso-spacerun:'yes';font-family:'Times New Roman';mso-fareast-font-family:Calibri; font-size:12.0000pt;\">Fuel&nbsp;: diesel<\/span><\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"font-family: 'Times New Roman'; font-size: 12pt;\">The supplier must provide &nbsp;necessary information for the best of &nbsp;the installation<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-indent: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">This incinerator with \u201cPYROLYTIC\u201d combustion must have:<\/span><\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt; background-position: initial initial; background-repeat: initial initial;\"><span style=\"font-family: 'Times New Roman'; font-size: 12pt;\">A combustion chamber of waste:<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"margin-left: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">* Perfectly tight door for the manual loading of waste.<\/span><span style=\"font-size: 12pt;\">&nbsp;The loading should be Manual, Batch Load<\/span><span style=\"font-size: 12pt;\">&nbsp;<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-indent: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">* A burner of lighting which the use is limited to the ignition of waste.<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"margin-left: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"margin-left: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on &nbsp;&nbsp;the outside sheet metal.<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-indent: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">*<\/span> <span style=\"font-size: 12pt;\">Composition of the refractory;<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">Refractory concrete :<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">. Thickness<\/span> <span style=\"font-size: 12pt;\">: \u2265100 mm<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">. Nature: 42% of Al203<\/span><\/p>\n<p class=\"MsoNormal\" style=\"margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">Insulate in fibrous panels :<\/span><\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">. Thickness: \u226575 mm<\/span><\/p>\n<p class=\"MsoNormal\" style=\"margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">Nature: Calcium silicate.<\/span><\/p>\n<p class=\"MsoNormal\" style=\"margin-left: 18pt; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">* Burner of lighting of waste, with fuel, standard<\/span> <i><span style=\"font-size: 12pt;\">mono-bloc casting guiding<\/span><\/i><span style=\"font-size: 12pt;\">&nbsp;<\/span><span style=\"font-size: 12pt;\">&nbsp;plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.<\/span><\/p>\n<p class=\"MsoNormal\" style=\"text-indent: 18pt; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">* Plate of combustion in Carborundum, avoiding the fixing of glass and slags.&nbsp;<\/span><\/p>\n<\/div>\n<\/div>\n<div id='gallery-2' class='gallery galleryid-439 gallery-columns-3 gallery-size-thumbnail'>\n<figure class='gallery-item'>\n<div class='gallery-icon landscape'><a href='https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/primary-chamber-start-to-firets-model-2'><img loading=\"lazy\" width=\"150\" height=\"150\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26d9eb03be.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a><\/div>\n<\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Capacity of destruction in weight: 60 Kg\/h. It should be able to operate not less than 10 hours\/day This incinerator<\/p>\n","protected":false},"author":1,"featured_media":5220,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[129],"tags":[800,350,642,154,143,465,346,135,172,644,801,802,803,136,167],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/5217"}],"collection":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/comments?post=5217"}],"version-history":[{"count":0,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/5217\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media\/5220"}],"wp:attachment":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media?parent=5217"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/categories?post=5217"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/tags?post=5217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}