{"id":5249,"date":"2021-06-23T04:19:38","date_gmt":"2021-06-23T04:19:38","guid":{"rendered":"https:\/\/www.medicalmate.net\/?p=5249"},"modified":"2021-06-23T04:19:38","modified_gmt":"2021-06-23T04:19:38","slug":"medical-incinerator-specification-2","status":"publish","type":"post","link":"https:\/\/incinerators.hiclover.com\/index.php\/2021\/06\/23\/medical-incinerator-specification-2\/","title":{"rendered":"Medical Incinerator Specification"},"content":{"rendered":"<figure class=\"post-featured-image\"><img loading=\"lazy\" width=\"960\" height=\"720\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26db6e0abf.jpg\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/figure>\n<div class=\"entry-content clearfix\">\n<div>\n<div><span style=\"color: rgb(0, 0, 0); background-color: rgba(0, 0, 0, 0);\">Capacity Not&nbsp;less&nbsp;than&nbsp;500Kg\/hr.<br \/>\nOperation 24hr-7days\/week&nbsp;continuous&nbsp;operation.<br \/>\nCombustion&nbsp;chamber 2&nbsp;combustion&nbsp;chamber.<br \/>\nTemp. First&nbsp;combustion&nbsp;chamber&nbsp;800-1000&nbsp;C.<br \/>\nSecandry&nbsp;combustion&nbsp;chamber&nbsp;1000-1200&nbsp;C,&nbsp;with&nbsp;the&nbsp;possibility&nbsp;to&nbsp;be&nbsp;upgraded&nbsp;to&nbsp;1400&nbsp;C.<br \/>\nCombustion&nbsp;Efficiency 99.99%<br \/>\nRetention&nbsp;time Of&nbsp;the&nbsp;flow&nbsp;gases&nbsp;not&nbsp;less&nbsp;than&nbsp;2&nbsp;Sec&nbsp;in&nbsp;the&nbsp;hot&nbsp;portion.<br \/>\nExcess&nbsp;Oxygen&nbsp;concentration Of&nbsp;primary&nbsp;combustion&nbsp;chamber&nbsp;3-6%&nbsp;max.<\/span><\/div>\n<div><img src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26db791acd.jpg\" border=\"0\" \/><span style=\"color: rgb(0, 0, 0); background-color: rgba(0, 0, 0, 0);\"><br \/>\nRefractory The&nbsp;chambers&nbsp;should&nbsp;be&nbsp;lined&nbsp;with&nbsp;high&nbsp;thermal&nbsp;insulating&nbsp;refractory&nbsp;bricks&nbsp;with&nbsp;suitable&nbsp;thickness&nbsp;and&nbsp;with&nbsp;highly&nbsp;temp.&nbsp;<br \/>\nresistance.&nbsp;Not&nbsp;less&nbsp;than&nbsp;1400&nbsp;C&nbsp;for&nbsp;the&nbsp;first&nbsp;combustion&nbsp;chamber,&nbsp;and&nbsp;not&nbsp;less&nbsp;than&nbsp;1600&nbsp;C&nbsp;for&nbsp;the&nbsp;secandry&nbsp;combustion&nbsp;chamber,&nbsp;and&nbsp;at&nbsp;the&nbsp;<br \/>\nsame&nbsp;time&nbsp;prevent&nbsp;the&nbsp;Temp.&nbsp;of&nbsp;the&nbsp;outside&nbsp;body&nbsp;of&nbsp;the&nbsp;chamber&nbsp;not&nbsp;higher&nbsp;than&nbsp;70&nbsp;C.<br \/>\nDoors Should&nbsp;be&nbsp;lined&nbsp;with&nbsp;the&nbsp;same&nbsp;bricks,&nbsp;and&nbsp;the&nbsp;edges&nbsp;lined&nbsp;with&nbsp;special&nbsp;suitable&nbsp;insulating&nbsp;material&nbsp;to&nbsp;prevent&nbsp;any&nbsp;gas&nbsp;escaping,&nbsp;and&nbsp;<br \/>\nthe&nbsp;doors&nbsp;should&nbsp;be&nbsp;kept&nbsp;under&nbsp;negative&nbsp;pressure&nbsp;during&nbsp;the&nbsp;operation.<br \/>\nAir&nbsp;Emission&nbsp;Control&nbsp;System With&nbsp;high&nbsp;destruction&nbsp;and&nbsp;removal&nbsp;efficiency&nbsp;(DRE).&nbsp;Not&nbsp;less&nbsp;than&nbsp;99.9999&nbsp;as&nbsp;per&nbsp;KEPA.<br \/>\nWet&nbsp;System If&nbsp;the&nbsp;system&nbsp;equiped&nbsp;with&nbsp;a&nbsp;CEMS&nbsp;washing&nbsp;the&nbsp;flow&nbsp;gas&nbsp;with&nbsp;water,&nbsp;then&nbsp;it&nbsp;should&nbsp;be&nbsp;manufactured&nbsp;from&nbsp;suitable&nbsp;anti&nbsp;<br \/>\ncorrossion&nbsp;materials,&nbsp;and&nbsp;equiped&nbsp;with&nbsp;pH&nbsp;meter&nbsp;to&nbsp;measure&nbsp;and&nbsp;neutralize&nbsp;the&nbsp;water.&nbsp;It&nbsp;should&nbsp;be&nbsp;able&nbsp;to&nbsp;use&nbsp;the&nbsp;water&nbsp;in&nbsp;closed&nbsp;recycled&nbsp;<br \/>\ncircuit&nbsp;many&nbsp;times&nbsp;before&nbsp;treating\/&nbsp;discharging&nbsp;into&nbsp;the&nbsp;sewage&nbsp;system&nbsp;in&nbsp;compliance&nbsp;with&nbsp;KEPARS.<br \/>\nChemical&nbsp;dosing It&nbsp;should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;suitable&nbsp;autochemical&nbsp;dosing&nbsp;system&nbsp;to&nbsp;control&nbsp;the&nbsp;pH&nbsp;for&nbsp;the&nbsp;water&nbsp;of&nbsp;the&nbsp;wet&nbsp;scrubber&nbsp;system&nbsp;<br \/>\nincluding&nbsp;sensors.<br \/>\nChimney It&nbsp;should&nbsp;be&nbsp;suitable&nbsp;with&nbsp;the&nbsp;capacity&nbsp;and&nbsp;the&nbsp;technical&nbsp;specifications,&nbsp;with&nbsp;height&nbsp;not&nbsp;less&nbsp;than&nbsp;12m&nbsp;from&nbsp;ground&nbsp;level.&nbsp;With&nbsp;easy&nbsp;<br \/>\nopennable&nbsp;sampling&nbsp;point&nbsp;equal&nbsp;about&nbsp;3&nbsp;inch,&nbsp;and&nbsp;the&nbsp;optimum&nbsp;sampling&nbsp;locations&nbsp;is&nbsp;at&nbsp;least&nbsp;8D&nbsp;downstream&nbsp;direction&nbsp;and&nbsp;2D&nbsp;upstream&nbsp;from&nbsp;any&nbsp;<br \/>\nflow&nbsp;disturbancies.<br \/>\nSampling&nbsp;point Should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;a&nbsp;platform&nbsp;located&nbsp;down&nbsp;the&nbsp;sampling&nbsp;point&nbsp;by&nbsp;a&nbsp;distance&nbsp;not&nbsp;less&nbsp;than&nbsp;1&nbsp;m,&nbsp;and&nbsp;equiped&nbsp;with&nbsp;suitable&nbsp;<br \/>\nstairs&nbsp;from&nbsp;ground&nbsp;to&nbsp;the&nbsp;port&nbsp;with&nbsp;comfortable&nbsp;slope.<br \/>\nAsh&nbsp;Removal It&nbsp;should&nbsp;be&nbsp;auto&nbsp;ash&nbsp;removal&nbsp;system.<br \/>\nFuel It&nbsp;should&nbsp;be&nbsp;dual&nbsp;system,&nbsp;such&nbsp;as&nbsp;diesel&nbsp;and&nbsp;natural&nbsp;gas.<br \/>\nFeeding&nbsp;System Should&nbsp;be&nbsp;auto&nbsp;feeding&nbsp;system&nbsp;into&nbsp;primary&nbsp;chamber.<br \/>\nControl&nbsp;Room Should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;a&nbsp;control&nbsp;panel&nbsp;shows&nbsp;Temp.&nbsp;of&nbsp;the&nbsp;combustion&nbsp;burners,&nbsp;gas&nbsp;monitoring,&nbsp;digital&nbsp;Temp.&nbsp;indecation&nbsp;for&nbsp;the&nbsp;<br \/>\nprimary\/secondary&nbsp;chambers,&nbsp;digital&nbsp;Temp.&nbsp;indication&nbsp;for&nbsp;the&nbsp;gases\u2026etc.&nbsp;it&nbsp;should&nbsp;be&nbsp;also&nbsp;Auto&nbsp;operation,&nbsp;burnures&nbsp;on\/off&nbsp;auto&nbsp;lamps&nbsp;switch,&nbsp;<br \/>\nauto&nbsp;start\/stop&nbsp;for&nbsp;air&nbsp;emission&nbsp;control&nbsp;system,&nbsp;auto&nbsp;gas&nbsp;continuous&nbsp;monitoring&nbsp;system&nbsp;reading&nbsp;and&nbsp;print&nbsp;out&nbsp;of&nbsp;gas&nbsp;emission&nbsp;parameters\u2026etc.<br \/>\nCooling&nbsp;System The&nbsp;primary&nbsp;chamber&nbsp;should&nbsp;be&nbsp;provided&nbsp;with&nbsp;auto&nbsp;cooling&nbsp;systemthrough&nbsp;nozzles&nbsp;to&nbsp;permit&nbsp;direct&nbsp;cooling&nbsp;if&nbsp;the&nbsp;Temp.&nbsp;will&nbsp;be&nbsp;<br \/>\nheigher&nbsp;than&nbsp;1100&nbsp;C.<br \/>\nInter-lock&nbsp;system The&nbsp;incinerator&nbsp;should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;inter-lock&nbsp;system&nbsp;to&nbsp;prevent&nbsp;feeding&nbsp;the&nbsp;waste&nbsp;to&nbsp;the&nbsp;primary&nbsp;chamber&nbsp;if&nbsp;the&nbsp;<br \/>\ncombustion&nbsp;Temp.&nbsp;less&nbsp;than&nbsp;500&nbsp;C.<br \/>\nFlue&nbsp;treatment&nbsp;and&nbsp;cleaning To&nbsp;consist&nbsp;a&nbsp;combined&nbsp;system&nbsp;(wet\/dry),&nbsp;using&nbsp;water,&nbsp;lime,&nbsp;active&nbsp;carbon&nbsp;and&nbsp;ceramic&nbsp;filters.<br \/>\nQuenching&nbsp;system\/Heat&nbsp;exchanger Should&nbsp;be&nbsp;made&nbsp;and&nbsp;manufactured&nbsp;from&nbsp;anti&nbsp;corrosion&nbsp;and&nbsp;acid&nbsp;attack&nbsp;materials&nbsp;such&nbsp;as&nbsp;stainless&nbsp;steel&nbsp;316&nbsp;or&nbsp;<br \/>\nequivalent.<br \/>\nNoise&nbsp;Level Not&nbsp;more&nbsp;than&nbsp;85&nbsp;dBA&nbsp;during&nbsp;normal&nbsp;operation.<br \/>\nInaddition The&nbsp;desigh&nbsp;should&nbsp;insure&nbsp;that&nbsp;responsive&nbsp;fail-safe&nbsp;control&nbsp;systems&nbsp;are&nbsp;used.<br \/>\nThe&nbsp;incinerator&nbsp;should&nbsp;be&nbsp;installed&nbsp;inside&nbsp;closed&nbsp;suitable&nbsp;building&nbsp;with&nbsp;good&nbsp;aeration&nbsp;and&nbsp;ventilation&nbsp;system.&nbsp;The&nbsp;building&nbsp;has&nbsp;<br \/>\nfacilities&nbsp;for&nbsp;off-loading&nbsp;of&nbsp;wastes&nbsp;from&nbsp;transport&nbsp;vehicles.&nbsp;Auto&nbsp;cleaning&nbsp;system&nbsp;for&nbsp;trucks&nbsp;and&nbsp;waste&nbsp;containers,&nbsp;and&nbsp;cool&nbsp;storage&nbsp;<br \/>\narea\u2026etc.<br \/>\nThe&nbsp;quotation&nbsp;should&nbsp;included&nbsp;list&nbsp;of&nbsp;original&nbsp;spare&nbsp;parts&nbsp;for&nbsp;7&nbsp;years.<br \/>\nThe&nbsp;quotation&nbsp;should&nbsp;include&nbsp;supervising,&nbsp;starting&nbsp;up&nbsp;and&nbsp;training&nbsp;of&nbsp;the&nbsp;operators&nbsp;and&nbsp;ministry&nbsp;of&nbsp;health&nbsp;engineers&nbsp;inside\/outside&nbsp;<br \/>\nKuwait.<br \/>\nDetailed&nbsp;drawings,&nbsp;catalogs&nbsp;should&nbsp;be&nbsp;included.<br \/><\/span><\/div>\n<\/div>\n<div id='gallery-2' class='gallery galleryid-445 gallery-columns-3 gallery-size-thumbnail'>\n<figure class='gallery-item'>\n<div class='gallery-icon landscape'><a href='https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/medical-incinerator-specification-2'><img loading=\"lazy\" width=\"150\" height=\"150\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26db804934.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a><\/div>\n<\/figure>\n<figure class='gallery-item'>\n<div class='gallery-icon landscape'><a href='https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/insertpic_9bb7-2'><img loading=\"lazy\" width=\"150\" height=\"150\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26db8654d3.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/a><\/div>\n<\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Capacity Not&nbsp;less&nbsp;than&nbsp;500Kg\/hr. Operation 24hr-7days\/week&nbsp;continuous&nbsp;operation. Combustion&nbsp;chamber 2&nbsp;combustion&nbsp;chamber. Temp. First&nbsp;combustion&nbsp;chamber&nbsp;800-1000&nbsp;C. Secandry&nbsp;combustion&nbsp;chamber&nbsp;1000-1200&nbsp;C,&nbsp;with&nbsp;the&nbsp;possibility&nbsp;to&nbsp;be&nbsp;upgraded&nbsp;to&nbsp;1400&nbsp;C. Combustion&nbsp;Efficiency 99.99% Retention&nbsp;time Of&nbsp;the&nbsp;flow&nbsp;gases&nbsp;not&nbsp;less&nbsp;than&nbsp;2&nbsp;Sec&nbsp;in&nbsp;the&nbsp;hot&nbsp;portion. Excess&nbsp;Oxygen&nbsp;concentration Of&nbsp;primary&nbsp;combustion&nbsp;chamber&nbsp;3-6%&nbsp;max. Refractory The&nbsp;chambers&nbsp;should&nbsp;be&nbsp;lined&nbsp;with&nbsp;high&nbsp;thermal&nbsp;insulating&nbsp;refractory&nbsp;bricks&nbsp;with&nbsp;suitable&nbsp;thickness&nbsp;and&nbsp;with&nbsp;highly&nbsp;temp.&nbsp; resistance.&nbsp;Not&nbsp;less&nbsp;than&nbsp;1400&nbsp;C&nbsp;for&nbsp;the&nbsp;first&nbsp;combustion&nbsp;chamber,&nbsp;and&nbsp;not&nbsp;less&nbsp;than&nbsp;1600&nbsp;C&nbsp;for&nbsp;the&nbsp;secandry&nbsp;combustion&nbsp;chamber,&nbsp;and&nbsp;at&nbsp;the&nbsp; same&nbsp;time&nbsp;prevent&nbsp;the&nbsp;Temp.&nbsp;of&nbsp;the&nbsp;outside&nbsp;body&nbsp;of&nbsp;the&nbsp;chamber&nbsp;not&nbsp;higher&nbsp;than&nbsp;70&nbsp;C. Doors<\/p>\n","protected":false},"author":1,"featured_media":5255,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[129],"tags":[692,154,143,484,850,155,851,759,159,803,852,488,611,669,853],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/5249"}],"collection":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/comments?post=5249"}],"version-history":[{"count":0,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/5249\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media\/5255"}],"wp:attachment":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media?parent=5249"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/categories?post=5249"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/tags?post=5249"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}