{"id":5306,"date":"2021-06-25T01:21:06","date_gmt":"2021-06-25T01:21:06","guid":{"rendered":"https:\/\/www.medicalmate.net\/?p=5306"},"modified":"2021-06-25T01:21:06","modified_gmt":"2021-06-25T01:21:06","slug":"design-standard-multiple-chamber-incinerator","status":"publish","type":"post","link":"https:\/\/incinerators.hiclover.com\/index.php\/2021\/06\/25\/design-standard-multiple-chamber-incinerator\/","title":{"rendered":"Design standard Multiple chamber incinerator"},"content":{"rendered":"<figure class=\"post-featured-image\"><img loading=\"lazy\" width=\"450\" height=\"300\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26ddf3a113.jpg\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"\" sizes=\"(max-width: 450px) 100vw, 450px\" \/><\/figure>\n<div class=\"entry-content clearfix\">\n<div>\n<div>\n<div>Waste&nbsp;type organics&nbsp;domestical&nbsp;&nbsp;waste<\/div>\n<div>Calorific&nbsp;value&nbsp;of&nbsp;waste 9,25&nbsp;MJ\/kg<\/div>\n<div>Ash&nbsp;content 20.80&nbsp;%<\/div>\n<div>Density 291&nbsp;Kg\/m3<\/div>\n<div>Waste&nbsp;quantity&nbsp;(kg&nbsp;per&nbsp;hr) 12,500<\/div>\n<div>Total&nbsp;Heat&nbsp;input&nbsp;(Gcal\/hr) 23.71<\/div>\n<div>organics&nbsp;domestical&nbsp;&nbsp;waste Solid Domestic&nbsp;waste,&nbsp;after&nbsp;separating&nbsp;the&nbsp;recyclable,&nbsp;such&nbsp;as:&nbsp;plastic,&nbsp;cloth,&nbsp;metal,&nbsp;paper,&nbsp;wood,&nbsp;glass,&nbsp;stones,&nbsp;etc.&nbsp;than&nbsp;larger&nbsp;10&nbsp;cms<\/div>\n<div>Design&nbsp;standard Multiple&nbsp;chamber&nbsp;incinerator&nbsp;to&nbsp;the&nbsp;design&nbsp;of&nbsp;EPA&nbsp;&nbsp;standards,&nbsp;Air&nbsp;pollution&nbsp;control<\/div>\n<div>Description&nbsp;of&nbsp;the&nbsp;Chimney Top&nbsp;mounted,&nbsp;self&nbsp;supporting<\/div>\n<div>Incinerator&nbsp;performance 150kg\/hr<\/div>\n<div>Refuse&nbsp; Hospital&nbsp;waste&nbsp;and&nbsp;carcasses<\/div>\n<div>Recommended&nbsp;Temperatures Minimum&nbsp;1000\u2070C<\/div>\n<div>Dimensions:<\/div>\n<div>\uf0b7Length&nbsp;<\/div>\n<div>\uf0b7Width&nbsp;<\/div>\n<div>\uf0b7Height&nbsp;<\/div>\n<div>\uf0b7Extra&nbsp;width&nbsp;for&nbsp;burners At&nbsp;least&nbsp;3000mm<\/div>\n<div>Loading&nbsp;door&nbsp;opening Minimum&nbsp;700mm&nbsp;x&nbsp;600mm<\/div>\n<div>Hearth&nbsp;area 5.00square&nbsp;meters<\/div>\n<div>Description&nbsp;or&nbsp;grate\/hearth A&nbsp;full&nbsp;hearth&nbsp;supplied&nbsp;to&nbsp;prevent&nbsp;contaminated&nbsp;liquids&nbsp;from&nbsp;flowing&nbsp;into&nbsp;the&nbsp;ash&nbsp;pit&nbsp;without&nbsp;being&nbsp;incinerated<\/div>\n<div>Primary&nbsp;chamber&nbsp;volume At&nbsp;least&nbsp;3&nbsp;cubic&nbsp;meters<\/div>\n<div>Mixing&nbsp;chamber&nbsp;volume At&nbsp;least&nbsp;1&nbsp;cubic&nbsp;meters<\/div>\n<div>Settling&nbsp;chamber&nbsp;volume At&nbsp;least&nbsp;3&nbsp;cubic&nbsp;meters<\/div>\n<div>Weight&nbsp;excluding&nbsp;chimney 15,&nbsp;000kg&nbsp;at&nbsp;manufacture<\/div>\n<div>Firing&nbsp;tools&nbsp;supplied Hoe,&nbsp;Poker&nbsp;and&nbsp;rake<\/div>\n<\/div>\n<\/div>\n<div id='gallery-2' class='gallery galleryid-459 gallery-columns-3 gallery-size-thumbnail'>\n<figure class='gallery-item'>\n<div class='gallery-icon landscape'><a href='https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/africa-engineer-instal-the-incineratoryd-model-hiclover-2'><img loading=\"lazy\" width=\"150\" height=\"150\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210529_60b26ddf9e270.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a><\/div>\n<\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Waste&nbsp;type organics&nbsp;domestical&nbsp;&nbsp;waste Calorific&nbsp;value&nbsp;of&nbsp;waste 9,25&nbsp;MJ\/kg Ash&nbsp;content 20.80&nbsp;% Density 291&nbsp;Kg\/m3 Waste&nbsp;quantity&nbsp;(kg&nbsp;per&nbsp;hr) 12,500 Total&nbsp;Heat&nbsp;input&nbsp;(Gcal\/hr) 23.71 organics&nbsp;domestical&nbsp;&nbsp;waste Solid Domestic&nbsp;waste,&nbsp;after&nbsp;separating&nbsp;the&nbsp;recyclable,&nbsp;such&nbsp;as:&nbsp;plastic,&nbsp;cloth,&nbsp;metal,&nbsp;paper,&nbsp;wood,&nbsp;glass,&nbsp;stones,&nbsp;etc.&nbsp;than&nbsp;larger&nbsp;10&nbsp;cms Design&nbsp;standard Multiple&nbsp;chamber&nbsp;incinerator&nbsp;to&nbsp;the&nbsp;design&nbsp;of&nbsp;EPA&nbsp;&nbsp;standards,&nbsp;Air&nbsp;pollution&nbsp;control Description&nbsp;of&nbsp;the&nbsp;Chimney Top&nbsp;mounted,&nbsp;self&nbsp;supporting Incinerator&nbsp;performance<\/p>\n","protected":false},"author":1,"featured_media":5309,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[129],"tags":[154,896,183,897,898,168,135,172,807,899,900,901,902,903,136],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/5306"}],"collection":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/comments?post=5306"}],"version-history":[{"count":0,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/5306\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media\/5309"}],"wp:attachment":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media?parent=5306"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/categories?post=5306"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/tags?post=5306"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}