{"id":6350,"date":"2021-07-10T21:42:24","date_gmt":"2021-07-10T21:42:24","guid":{"rendered":"https:\/\/www.medicalmate.net\/?p=6350"},"modified":"2021-07-10T21:42:24","modified_gmt":"2021-07-10T21:42:24","slug":"incinerator-with-ease-of-jealousy-in-weight-60-kg-h","status":"publish","type":"post","link":"https:\/\/incinerators.hiclover.com\/index.php\/2021\/07\/10\/incinerator-with-ease-of-jealousy-in-weight-60-kg-h\/","title":{"rendered":"Incinerator with Ease of Jealousy in weight: 60 Kg\/h."},"content":{"rendered":"<figure class=\"post-featured-image\"><img loading=\"lazy\" width=\"449\" height=\"300\" src=\"https:\/\/www.medicalmate.net\/wp-content\/uploads\/2021\/05\/20210530_60b36c6a483f2.jpg\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"\" sizes=\"(max-width: 449px) 100vw, 449px\" \/><\/figure>\n<div>\n<div>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\">Ability of destruction in weight: 60 Kg\/h.<\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt;\">It should be able to work less 10 hours\/day<\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\">This incinerator must have the ability to destruct all combustible wastes produced by hospitals, private practices, labs, institutes, etc&#8230;<\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\">Design Specification: Types A, B, C, D, and E of medical waste&nbsp;<\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\">&#8220;PYROLYTIC&#8221; combustion, by simply controlling the gasification of waste.<\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\">The incinerator must prevent the discharge of smoke and dust that is fine, (Smokeless) during the loadings.<\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt;\">It should have the ability to reduce the quantity of wastes from 98%.<\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt;\">It should be able to hold emission in the next burn with gas residence of less than two seconds.<\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\">The incineration should be completely free of visible smoke&nbsp;as well as offensive odours.<\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt;\">The lower volt electricity (L.C.P) of the waste will be 3,500 kcal\/kg<\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt; margin-left: 45pt;\">The Temperatures of combustionMinimum will be 850oC and maximum 1400oC<\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt; margin-left: 45pt;\">Post combustion: 1100oC.<\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\">The Inner diameter of the Chimney: \u00d8 400 and its elevation: 8 m<\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\">The Volume of the combustion chamber: 1.200 L<\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\">The Dimension of this doorway for loading cm: 70\u00d770.<\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\">Burner operation should be Automatic On\/Off<\/p>\n<p class=\"16\" style=\"margin-top: 6pt; margin-bottom: 12pt; line-height: 14.4pt; background-position: initial initial; background-repeat: initial initial;\">Gas: diesel<\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt; background-position: initial initial; background-repeat: initial initial;\">The provider must supply necessary information for the top of &nbsp;this installment<\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-indent: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">This incinerator with&#8221;PYROLYTIC&#8221; combustion must have:<\/p>\n<p class=\"16\" style=\"margin-bottom: 0pt; background-position: initial initial; background-repeat: initial initial;\">A combustion chamber of waste:<\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"margin-left: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">* Totally tight doorway for the manual loading of waste.&nbsp; The loading should be Manual, Batch Load&nbsp;<\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-indent: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">* A burner of lighting that the use is restricted to the ignition of waste.<\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"margin-left: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">* Frontage of loading with door seals ended up on hinges, wheel of screw plug, elastic joint, and stuffing insulating from refractory.<\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"margin-left: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">* The insulation of the combustion chamber should be made up of refractory bricks, so using a high content of aluminium and insulates bricks in order to guarantee a minimum temperature on &nbsp;&nbsp;the exterior sheet metal.<\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-indent: 18pt; text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">* Composition of this refractory;<\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">Refractory concrete:<\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">. Nature: 42 percent of Al203<\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">Insulate in fibrous panels:<\/p>\n<p class=\"MsoNormal\" style=\"margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">. Thickness: \u226575 mm<\/p>\n<p class=\"MsoNormal\" align=\"justify\" style=\"text-align: justify; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">Nature: Calcium silicate.<\/p>\n<p class=\"MsoNormal\" style=\"margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\">* Burner of lighting of waste, with fuel, standard mono-bloc casting directing stirring flame, lighting and safety of digital ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.<\/p>\n<p class=\"MsoNormal\" style=\"margin-left: 18pt; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">* Burner of lighting of waste, with fuel, standard<\/span> <i><span style=\"font-size: 12pt;\">mono-bloc casting guiding<\/span><\/i><span style=\"font-size: 12pt;\">&nbsp;<\/span><span style=\"font-size: 12pt;\">&nbsp;plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.<\/span><\/p>\n<p class=\"MsoNormal\" style=\"text-indent: 18pt; margin-bottom: 0pt; font-family: 'Times New Roman'; font-size: 12pt;\"><span style=\"font-size: 12pt;\">* Plate of combustion in Carborundum, avoiding the fixing of glass and slags.&nbsp;<\/span><\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Ability of destruction in weight: 60 Kg\/h. It should be able to work less 10 hours\/day This incinerator must have<\/p>\n","protected":false},"author":1,"featured_media":6351,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[129],"tags":[1227,800,350,154,143,135,172,1228,644,801,802,803,136,167],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/6350"}],"collection":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/comments?post=6350"}],"version-history":[{"count":0,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/posts\/6350\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media\/6351"}],"wp:attachment":[{"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/media?parent=6350"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/categories?post=6350"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incinerators.hiclover.com\/index.php\/wp-json\/wp\/v2\/tags?post=6350"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}